Load Break Switch 12kV (FZW28F)

On the 12kV feeding line, when the error happened at one tributary line of the T type link users, normally it will cause the main line or adjacent users power cut accident, the investing make known this kind of accident takes 20%-30% or higher percentage in all power distribution accident, the result is enlarged power cutting scope and cause responsibility disputation.
DESCRIPTIONMAIN TECHNICAL PARAMETER

Model NO.

FZW28-12F

Series

Three

Structure of Operating

Electric

Certification

CE, ISO9001

Brand

Vacem

Power Frequency Withstand Voltage

42/48kV

Lightning Impulse Withstand Voltage

75/85kV(Peak)

Rated Short Time Withstand Current

16kA

Rated Cable Charged Breaking Time

20A

Mechanical Life Time

10,000 times

Trademark

VACEM

Origin

Wenzhou, China


1.General description

    On the 12kV feeding line, when the error happened at one tributary line of the T type link users, normally it will cause the main line or adjacent users power cut accident, the investing make known this kind of accident takes 20%-30% or higher percentage in all power distribution accident, the result is enlarged power cutting scope and cause responsibility disputation.

    Mounted a user boundary load break switch (also name watchdog) at the above T-type connecting point is the ideal solution to the above accident.


2.Main function characteristic

    Automatically cut single phase earthing fault: when users tributary line cause single phase earthing fault, the boundary switch will open automatically, other distribution line users of the substation and feeding line will be without influence; isolation interphase short circuit fault automatically.

    When the tributary line cause interphase short-circuit fault, boundary switch will open at once after out-wire protection tripping. After the substation reclose, fault line is isolated passively,other distribution users in feeding line resume power supply rapidly (equal to a transient fault).

    Quick localization of fault: the tributary line fault cause boundary switch protection action, only the accident user cause power cut and by itself report the fault information, the power company could dispatch worker to life investigation;if the boundary switch match with communication module, it could transmit message to electricity management center.

    Monitoring users load, boundary switch could configure wired or wireless communication enclosure to monitor data and transmit to electricity management center,make the achievement of real-time data monitoring of users load in long distance.

    Function of network running, it could be used in network lines,function of measurement,monitor voltage,current,frequency and quantity of electricity of lines,and transmit to management center in long distance.Function of harmonic analyzing.to supply reliable basis for pollution administration of electricity net afterwards.


3.Condition of using environment

a.Altitude:≤2000m

b.Relative humidity:≤90%(25℃)

c.Max.wind speed:≤25m/s

d.Ambient temperature:-40℃~85℃

e.Max.day temperature gap:25℃

f.Max.ice-covering thickness:10 mm